DSpace

King Saud University Repository >
King Saud University >
ACADEMIC PUBLISHING & PRESS >
Journal of the King Saud University - Engineering Sciences >

Please use this identifier to cite or link to this item: http://hdl.handle.net/123456789/66

Title: Experimental study of liquid distribution in packed column
Authors: Ibrahim, Abmed A.
Keywords: Liquid Distribution
Packed Column
Engineering
Issue Date: 1998
Publisher: King Saud University
Citation: Journal of King Saud University, Engineering Sciences: 10 (2); 271-284
Abstract: This work presents the results of an experimental study ofIiquid distribution for the air/water system, carried out in 0.3m diameter Perspex column packed with 25mm plastic pall rings of equal length and diameter. Measurements of flow rates were performed at different radial and axial positions at the end of the column. The column was operated with gas flow rates varying over the ranges of 0.0 to 1.2kg/m2s, liquid flow rates varying over the range 9.9 to 19.9kg/m2s and with the ratio of the initial flow to the bulk and wall regions varying between O. 8 and 0.5. The packing height was increased by the addition of a fixed amount at a time, until a height of 1.05m was reached.
URI: http://hdl.handle.net/123456789/66
Appears in Collections:Journal of the King Saud University - Engineering Sciences

Files in This Item:

File SizeFormat
Experimental study of liquid distribution in packed column.pdf350.17 kBAdobe PDFView/Open

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

DSpace Software Copyright © 2002-2007 MIT and Hewlett-Packard - Feedback